CellTec Pty. Ltd.
Home | Services | Products | Resources | Contact   | ABN: 44 214 213 918 
 latest news and Information
18-11-2005
CellTec 2005-06 Website

Safety Technology - Single Light Beam Devices

 SLS 78/R
SLS 78/R - Through-beam Safety Light Barrier Type 4

Through-beam safety light barrier is an active optoelectronic protective device (AOPD) type 4 according to EN-/IEC 61496-1, -2. It consists of transmitter and receiver.

The Type 4 light barrier, like the ROBUST light grid system, is designed for operation under unfavourable environmental conditions. With the help of deflecting mirrors, security barriers on several axes may also be created.

Advantages
  • Range from 0 to 60 m
  • Integrated lens contamination monitoring via sensor status indication (LED)
  • Integrated lens heating system for outside use or use in extreme environmental conditions
  • Glass optics - high mechanical and chemical resistance
  • Easy to mount with plug-in terminals without screws
  • Ready-to-plug-in version available on request
Product Information - SLS 78/R
Product Information - Data Sheet SLS 78/R
Product Information - Connection and Operating Instructions

 LS 763
LS 763 - Through-beam Safety Light Barriers (AOPD type 2)

In conjunction with a test monitoring unit, such as for instance the TNT 35 or MSI, this opto-sensor with test input constitutes an active optoelectronic protective device of type 2.

Advantages
  • Infrared light protective throughbeam photoelectric sensor with high performance reserve
  • Activation input for testing and interlinking
  • Compact construction with shock-resistant metal housing and glass optics
  • LED indicator in transmitter and receiver for function monitoring
  • PNP transistor output for PLC applications
  • Flexible PUR connection cable for industrial application
Product Information - LS 763
Product Information - Data Sheet LS 763/4.8, 2500
Product Information - Data Sheet LS 763/4.8 L8

 LS 92/4.8
LS 92/4.8 - Through-beam Safety Light Barriers (AOPD type 2)

In conjunction with a test monitoring unit, such as for instance the TNT 35 or MSI-s/R, this opto-sensor with test input constitutes an active optoelectronic protective device of type 2.

Advantages
  • Through-beam safety light barrier with high function reserve
  • Activating input for testing and cross linkage of the sensor
  • Compact design with sturdy housing of die casted zinc and glass optical parts for high protection against external influences
  • Optional bright/dark switching via pole reversal of operating voltage
  • Electrical connection with M12 circular plug-in connection, 6-pin standard plug or cable
  • Continuous fastening holes for quick assembly
Product Information - LS 92/4.8
Product Information - Data Sheet LS 92/4.8

 SLS 46
SLS 46 - Through-beam Safety Light Barriers (AOPD type 2)

In conjunction with a test monitoring unit, such as for instance the TNT 35 or MSI, this opto-sensor with test input constitutes an active optoelectronic protective device of type 2.

Advantages
  • Infrared light protective throughbeam photoelectric sensors with high performance reserve
  • Solid plastic housing, protection class IP 67 for industrial application
  • Wide voltage range 10 … 30V with PNP switching output for PLC applications
  • Activation input for testing and interlinking
Product Information - SLS 46
Product Information - Data Sheet SLS 46/44.8-S12, SLS 46/44.8, 2000
Product Information - Data Sheet SLS 46/44.8, 300-S12

 SLS 78M/P-1730-T2-4
SLS 78M/P-1730-T2-4 - Through-beam Safety Light Barriers (AOPD type 2)

In conjunction with a test monitoring unit, such as for instance the TNT 35 or MSI-s/R, this opto-sensor with test input constitutes an active optoelectronic protective device of type 2.

Advantages
  • Through-beam safety light barriers with high output in infra red light
  • Sturdy metal housing with glass lens in enclosure rating IP 65 for industrial use
  • Activating input for testing and connecting of the sensor
  • pnp transistor output for PLC operations
  • Connection via M12 circular plug-in connection
  • Intergrated lens heating system
Product Information - SLS 78M/P-1730-T2-4
Product Information - Data Sheet SLS 78M/P
Product Information - Data Sheet SLS 78M/PR

 SLSR 8
SLSR 8 - Through-beam Safety Light Barriers (AOPD type 2)

In conjunction with a test monitoring unit, such as for instance the TNT 35 or MSI, this opto-sensor with test input constitutes an active optoelectronic protective device of type 2.

Advantages
  • A²LS - active suppression of extraneous light
  • Push-pull switching outputs
  • M12 turning connector
  • Visible red light
Product Information - SLSR 8
Product Information - Data Sheet SLS8 R

 SLSR 95/44.8L
SLSR 95/44.8L - Through-beam Safety Light Barriers (AOPD type 2)

In conjunction with a test monitoring unit, such as for instance the TNT 35 or MSI-s/R, this opto-sensor with test input constitutes an active optoelectronic protective device of type 2.

Advantages
  • Through-beam safety light barrier with high function reserve in visible red light
  • Micro design with glass cover and sturdy housing of die casted zinc in enclosure rating IP 67 for industrial use
  • Activating input for function test
  • Antibonding switching outputs for bright/dark switching and/or as control function
  • 2 display LEDs in transmitter and receiver for status display during alignment and operation
  • Continuous fastening holes and M12 circular plug-in connections for quick mounting
  • EC conformity declaration for safety components according to EC machine regulation annex II,C
Product Information - SLSR 95/44.8L
Product Information - Data Sheet SLS 95/44.8L

 SLS96M/K
SLS96M/K - Through-beam Safety Light Barriers (AOPD type 2)

In conjunction with a test monitoring unit, such as for instance the TNT 35 or MSI-s/R, this opto-sensor with test input constitutes an active optoelectronic protective device of type 2.

Advantages
  • Through-beam safety light barriers category 2 (testing) with high function reserve in visible red light or infra-red light
  • Sturdy metal housing with glass covering in or robust plastic housing enclosure rating IP 67 for industrial use
  • Far-reach voltage range 10-30 V with pnp output for PLC applications
  • Activation input for connection or function test
  • 2 displays each on transmitter and receiver for status display during start-up and operation
  • Lens heating system combined with the ability to withstand low temperatures
  • Connection via M12 circular plug-in connection or comfortable terminal space
Product Information - SLS96M/K
Product Information - Data Sheet SLS96M/P
Product Information - Data Sheet SLS96K/P

 SRK 96
SRK 96 - Reflective Safety Light Barrier Type 2

Consisting of a red-light laser barrier and a special reflector, this system qualifies for safety class Type 2 in accordance with EN/IEC 61496-1, -2 when used in conjunction with a TNT test monitoring unit or with MSI modular safety interface. This new sensor technology offers the advantages of economical and quick installation as well as simple alignment.

Advantages
  • Reflective Safety Light Barrier, Type 2, in accordance with EN/IEC 61496-1, -2
  • Range 6 m
  • Easy to align due to visible red light
  • Wiring is only on the active side
  • Activation input for testing and series connection
  • No manipulation possible by standard reflectors or revlective foil
Product Information - SRK 96
Product Information - Data Sheet SRK 96
Product Information - Connection and Operating Instructions

 2005 CellTec Pty. Ltd. All rights reserved. Phone: 03 8360 8533, Fax: 03 8360 8544