| Safety Technology - Light Curtains |
COMPACT safety light curtains and multiple light beam safety devices
Are active optoelectronic protective devices (AOPD) type 4 according to EN 61496-1, -2 and/or IEC 61496-1, -2.
The system consists of a transmitter and a receiver, and is obtainable as a light curtain with 14 mm and 30 mm resolution or as a multiple light beam safety devices with 50 mm and 90 mm resolution. The design may include either two, three or four beams. Its range of functions is flexible and can be extended at will by the use of external interface modules of the MSI series.
Advantages
- Maintenance-free due to failsafe OSSD semiconductor outputs
- Interference between adjacent devices can be avoided by selecting separate transmission channels
- Multiple evaluation process d-scan for environments with extreme infrared impulse light interference (e.g. welding sparks, photoflash lamps)
- Cascade connection of several devices possible
- Easy to connect due to plug-in terminal device
- Functions can be flexibly expanded by adding external safety interface components MSI
- Integrated self-diagnostics system for easy diagnostics on-site and PC-supported diagnostics in the workshop
|
|
|
|
|
 |
|
COMPACT safety light curtains and multiple light beam safety devices
Are active optoelectronic protective devices (AOPD) type 4 according to EN 61496-1, -2 and/or IEC 61496-1, -2.
The system consists of a transmitter and a receiver, and is obtainable as a light curtain with 14 mm and 30 mm resolution or as a multiple light beam safety devices with 50 mm and 90 mm resolution. The design may include either two, three or four beams. Its range of functions is flexible and can be extended at will by the use of external interface modules of the MSI series.
The well established Compact safety light curtain is now available as the COMPACT EX 1, which is suitable for use in areas where there is risk of explosion either in zone 2 (gas) or zone 21 (dust)
Advantages
- Maintenance-free due to failsafe OSSD semiconductor outputs
- Interference between adjacent devices can be avoided by selecting separate transmission channels
- Multiple evaluation process d-scan for environments with extreme infrared impulse light interference (e.g. welding sparks, photoflash lamps)
- Cascade connection of several devices possible
- Easy to connect due to plug-in terminal device
- Functions can be flexibly expanded by adding external safety interface components MSI
- Integrated self-diagnostics system for easy diagnostics on-site and PC-supported diagnostics in the workshop
|
|
|
|
|
 |
|
Are active optoelectronic protective devices (AOPD) type 4 according to EN 61496-1, -2 and/or IEC 61496-1, -2.
The system consists of a transmitter and a receiver, and is obtainable as a light curtain with 14 mm and 30 mm resolution or as a multiple light beam safety devices with 50 mm and 90 mm resolution. The design may include either two, three or four beams. Its range of functions is flexible and can be extended at will by the use of external interface modules of the MSI series.
The well established Compact safety light curtain is now available as the COMPACT EX 2, which is suitable for use in areas where there is risk of explosion either in zone 2 (gas) or zone 22 (dust).
Advantages
- Maintenance-free due to failsafe OSSD semiconductor outputs
- Interference between adjacent devices can be avoided by selecting separate transmission channels
- Multiple evaluation process d-scan for environments with extreme infrared impulse light interference (e.g. welding sparks, photoflash lamps)
- Cascade connection of several devices possible
- Easy to connect due to plug-in terminal device
- Functions can be flexibly expanded by adding external safety interface components MSI
- Integrated self-diagnostics system for easy diagnostics on-site and PC-supported diagnostics in the workshop
|
|
|
|
|
 |
|
COMPACTplus-s Function Package standard
COMPACTplus safety light curtains and multiple light beam safety devices are Active Opto-electronic Protective Devices (AOPDs) of type 4 as defined by EN/IEC 61496-1 and (pr)EN/IEC 61496-2.
The aim of the COMPACTplus range is to live up to any future expectations in terms of top functionality, flexible integration and ease of operation. As an extension of the tried and tested COMPACT range, COMPACTplus incorporates as a bonus a number of additional fully integrated functions, such as for example a startup/restart interlock, electronic device monitoring and blanking. The various interface options that are available make it possible to connect the system at will either to conventional safety components or to safety bus systems.
COMPACTplus-s
For standard tasks, with switch-controlled restart interlock and electronic device monitoring function, as well as an additional contact-equipped safety circuit.
Advantages
- Integrated functions such as:
- startup testing
- restart interlock
- device monitoring
- Additional connection available for contact-equipped safety sensor
- Interface subassemblies:
- semiconductor output
- relay output
- AS-i Safety
- PROFIBUS DP (in Preparation)
- (other bussystems on demand)
- Lokal socket or sensor connection module (optional)
- “SafetyLab“ configuration and diagnosis software for the PC
- Insertable parameter module stores the device parameters so that components can easily be replaced
- Infrared interface for PC-supported configuration and on-site diagnosis
- Start-up/restart interlock, optionally by means of 2 start buttons
- Static and dynamic relay monitoring
- MultiScan, beam-related or scan-related multiple evaluation
- Additional two-channel switch-off circuit
|
|
|
|
|
 |
|
COMPACTplus-b Function Package blanking
COMPACTplus safety light curtains are Active Opto-electronic Protective Devices (AOPDs) of type 4 as defined by EN/IEC 61496-1 and (pr)EN/IEC 61496-2.
COMPACTplus-b
Safety light curtains with additional blanking functions (fixed and/or floating) plus reduced resolution of the protective field as well.
Advantages
- Integrated functions such as:
- startup testing
- restart interlock
- device monitoring
- Blanking
- Additional connection available for contact-equipped safety sensor
- Interface subassemblies:
- semiconductor output
- relay output
- AS-i Safety
- PROFIBUS DP (in Preparation)
- (other bussystems on demand)
- Lokal socket or sensor connection module (optional)
- Safety key for quick and easy parameterisation of protection zone blanking areas (Blanking)
- “SafetyLab“ configuration and diagnosis software for the PC
- Insertable parameter module stores the device parameters so that components can easily be replaced
- Infrared interface for PC-supported configuration and on-site diagnosis
- Start-up/restart interlock, optionally by means of 2 start buttons
- Static and dynamic relay monitoring
- MultiScan, beam-related or scan-related multiple evaluation
- Additional two-channel switch-off circuit
- Fixed and floating blanking by safety key programming or key buttons
- Freely determinable number and size of blanking zones
- Reduced resolution also in partial areas of the protection zone
- Position status signals for warning fields and the like
|
|
|
|
|
 |
|
COMPACTplus-m Function Package muting
Safety light curtains and multiple light beam safety devices with integrated muting
COMPACTplus safety light curtains and multiple light beam safety devices are Active Opto-electronic Protective Devices (AOPDs) of type 4 as defined by EN/IEC 61496-1 and (pr)EN/IEC 61496-2.
COMPACTplus-m
Safety Light Curtains, Multiple Light Beam Safety Devices and Transceivers with the “Muting” function package for bridging the safety device for a limited period, with, for example, proper material transport through the protective field.
Advantages
- Integrated functions such as:
- startup testing
- restart interlock
- device monitoring
- Muting
- Muting-Override
- Additional connection available for contact-equipped safety sensor
- Muting design variant as transceiver with direct connection to as many as 4 muting sensors and muting lamps based on M12 connection technology
- Interface subassemblies:
- semiconductor output
- relay output
- AS-i Safety
- PROFIBUS DP (in Preparation)
- (other bussystems on demand)
- Lokal socket or sensor connection module (optional)
- Integrated, monitored override function in accordance with the most recent safety requirements for the safe release of material after switching off
- “SafetyLab” configuration and diagnosis software for the PC
- Insertable parameter module stores the device parameters so that components can easily be replaced
- Infrared interface for PC-supported configuration and on-site diagnosis
- Start-up/restart interlock, optionally by means of 2 start buttons
- Static and dynamic relay monitoring
- MultiScan, beam-related or scan-related multiple evaluation
- Additional two-channel switch-off circuit
- 2-, 3- or 4-sensor muting
- Transmitter/receiver or transceiver/reflection mirror principle
- Additional control signals for muting and muting timer
|
|
|
|
|
 |
|
COMPACTplus-i Function Package initiation
Safety light curtains
COMPACTplus safety light curtains are Active Opto-electronic Protective Devices (AOPDs) of type 4 as defined by EN/IEC 61496-1 and (pr)EN/IEC 61496-2.
The aim of the COMPACTplus range is to live up to any future expectations in terms of top functionality, flexible integration and ease of operation. As an extension of the tried and tested COMPACT range, COMPACTplus incorporates as a bonus a number of additional fully integrated functions, such as for example a startup/restart interlock, electronic device monitoring and blanking. The various interface options that are available make it possible to connect the system at will either to conventional safety components or to safety bus systems.
COMPACTplus-i
Safety light curtains with the “Initiation” function package to not only protect with the safety device, but rather to also provide safety-related control of the production machine.
Advantages
- Integrated functions such as:
- startup testing
- Start-up/restart interlock, optionally by means of 2 start buttons
- device monitoring, static and dynamic
- single break / double break control
- Blanking and reduced resolution
- Bypass control
- Additional connection available for contact-equipped safety sensor
- Interface subassemblies:
- semiconductor output
- relay output
- AS-i Safety
- PROFIBUS DP (in Preparation)
- (other bussystems on demand)
- Insertable parameter module stores the device parameters so that components can easily be replaced
- Infrared interface for PC-supported configuration and on-site diagnosis
- “SafetyLab” configuration and diagnosis software for the PC
- multiple evaluation parameterizable
- fixed or changeable cycle operating mode
|
|
|
|
|
 |
|
Diagnostic and Parameterizing Software for COMPACTplus safety sensors
SafetyLab facilitates the diagnosis and parameterizing of COMPACTplus safety light curtains and multi-beam safety light curtains from firmware version 3.10 and upward. The PC software supports the COMPACTplus functional packages designated by the suffixes –b (blanking), -m (muting) and –i (machine cycle control). As with a safety PLC system, functions, control signals and notification messages can to a great extent be freely selected and assigned to the input and output channels of the receiver, up to the number of 15. This means that the COMPACTplus safety sensors can be ideally adapted to the task in hand, based on the specifications of the machine.
Advantages
- Application-specific parameterizing of muting operating modes, signal sources, time frames and lamp parameters
- Application-adapted parameterizing, in conformity with standards, of blanking and machine cycle control functions to ensure the safety of folding presses
- Online diagnosis with cleartext messages and visualisation of infrared light axes
- Powerful data recorder function, with graphic display of timed signal characteristics
- Ideal process adaptation of the safety sensors, through the incorporation and linking in of additional release signals
- Maximum reliability and availability, as a result of the adjustable filter function for external signals (e.g. muting signals)
- User management by means of wizard or expert mode
Function packages
SafetyLab can be used with all available functional packages of the COMPACTplus series from firmware version 3.10 or later.
- COMPACTplus-b (blanking)
- COMPACTplus-m (muting)
- COMPACTplus-i (machine cycle control)
|
|
|
|
|
 |
|
Type 2 Safety light curtains and multiple light beam safety devices
Machines that present a low risk of injury and have limited space available require opto-electronic safety devices that are both compact and economical.
ECO, the innovative Type 2 Safety light curtains and multiple light beam safety devices, fulfill both of these crucial requirements. Available in a variety of protective heights, their housing has a cross-section of just 17 mm x 33 mm.
ECO devices comply with the IEC 61496-1, -2 and have received European type approval from TÜV PRODUCT SERVICE in cooperation with the German BIA (Trade Association Institute for Industrial Safety; optical part IEC 61496-2). Various test monitoring units such as TNT 35 or safety interface components from the MSI series (or PLC solutions with added relays) can be used with the application.
Advantages
- Extremely small and sturdy housing (cross section 17 mm x 33 mm)
- Interference between adjacent devices can be avoided by selecting separate transmission channels
- Simple connection due to M12 connector
- Possible to integrate a stepping-behind protection by cascading several devices
- Functions (e.g. cyclical testing in intervals of 2 s, restart interlock, muting) can be flexibly expanded by adding type 2 interface components MSI
- Self-diagnosis system for PC-supported visualization and diagnosis
- Contamination and error signal output to PLC
|
|
|
|
|
 |
|